Silīcija karbīda cauruļveida membrāna

 

Nē. Tips Izmērs Caurumu numurs Garums
(mm)
filtrēšanas zona
(m2)
Filtrēšanas precizitāte (nm) Attēls
1
 
JMtech-SICT-25-3-19-1178
 
productcate-145-92 19
 
1178
 
0.21
 
40/100/500
 
productcate-147-126
2
 
JMtech-SICT-30-4-19-1016
 
productcate-173-115 19
 
1016
 
0.24
 
40/100/500
 
productcate-147-126
3
 
JMtech-SICT-31-4.2-19-1100-H
 
productcate-677-450 19
 
1100 0.31
 
40/100/500
 
productcate-150-137
4
 
JMtech-SICT-32-3.8-19-1100
 
productcate-172-97 19
 
1100
 
0.25
 
40/100/500
 
productcate-147-126
5
 
JMtech-SICT-32-3.8-19-1200
 
productcate-172-97 19
 
1200
 
0.27
 
40/100/500
 
productcate-147-126
6
 
JMtech-SICT-40-4-37-1200
 
productcate-153-112 37
 
1200
 
0.56
 
20/40/100/500
 
productcate-151-132
7
 
JMtech-SICT-40-5.6-19-1828.8-H
 
productcate-158-103 19
 
1828.8 0.71
 
20/40/100/500
 
productcate-159-137
8
 
JMtech-SICT-40-5.6-19-1500-H
 
productcate-158-103 19
 
1500 0.58
 
20/40/100/500 productcate-159-137
9
 
JMtech-SICT-40-4-37-1500-H
 
productcate-679-468 37
 
1500 0.81
 
20/40/100/500
 
productcate-156-140
10
 
JMtech-SICT-46-4-61-1230
 
productcate-697-514 61
 
1230
 
0.92
 
20/40/100/500
 
productcate-161-142
11
 
JMtech-SICT-46-X-81-1230-F
 
productcate-492-464 81
 
1230
 
1.27
 
20/40/100/500 productcate-154-137
12
 
JMtech-SICT-46-2.7-127-1230 productcate-130-87 127 1230
 
1.32 20/40/100/500
 
productcate-151-132
13
 
JMtech-SICT-50-4.9-37-1500-H
 
productcate-173-114 37
 
1500
 
1
 
40/100/500
 
productcate-156-140
14
 
JMtech-SICT-50-3.76-61-1500-H
 
productcate-158-139 61
 
1500
 
1.21
 
40/100/500
 
productcate-139-138
15
 
JMtech-SICT-146-4.3-524-1100
 
membrane 524
 
1100
 
7.8
 
40/100/500
 
productcate-163-145
16
 
JMtech-SICT-190-3.2-1701-1500
 
tubular membrane 1701
 
1500
 
25
 
40/100/500
 
productcate-148-132
17
 
JMtech-SICT-166-3-1086-880
 
productcate-831-634 1086
 
880
 
9.8
 
40/100/500
 
productcate-126-145

 

Piezīmes:piemērs"JMtech-SICT-25-3-19-1178"
Jmtech: Jianmo uzņēmuma saīsinājums
SICT: SIC cauruļveida membrāna
25: diametrs ir 25 mm
3: kanāla diametrs 3 mm
19:kanāla daudzums 19个
1178: garums 1178 mm
JMtech-SICT-40-5.6-19-1828.8-H Apzīmē sešstūrus
JMtech-SICT-46-X-81-1230-F 'F' apzīmē sektora formu

Kā viens no vadošajiem cauruļveida membrānu ražotājiem un piegādātājiem Ķīnā, mēs sirsnīgi sveicam jūs mūsu rūpnīcas vairumtirdzniecībā pēc pasūtījuma izgatavotas cauruļveida membrānas. Lai iegūtu vairāk lētu produktu, sazinieties ar mums tūlīt.

Nosūtīt pieprasījumu